Technical Data

Thermal imaging camera

GTC 600 C

Article number

‎3 601 K83 501‎‎‎‎

Resolution of infrared sensor

256 × 192 px

Thermal sensitivityA)

≤ 50 mK

Spectral range

8–14 μm

Field of view (FOV)B)

40° × 30°

Focus distanceB)

≥ 0.3 m

Focus

Fixed

Thermal image refresh rate

≤ 9 Hz

Surface temperature measuring rangeB)

–20 °C to +600 °C

Surface temperature measuring accuracyB)C)D)
–20 °C … ≤ +10 °C
> +10 °C … ≤ +100 °C
> +100 °C


±4 °C
±2 °C
±2 %

Temperature resolution

0.1 °C

Display type

TFT

Display size

3.5"

Display resolution

320 × 240 px

Integrated visual camera resolution

640 × 480 px

Image format

.jpg

Audio format

.wav

Elements saved per saving process

1 × thermal image (screenshot),
1 × real visual image incl. temperature values (metadata),
1 × voice note if applicable

Max. number of images in internal image memory

600

Max. number of images with a 10 s voice note each in internal image memory

350

Max. altitude

2000 m

Pollution degree according to IEC 61010-1

2E)

Relative air humidity max.B)

90 %

Rechargeable battery (Li-ion)

12 V

Rechargeable battery operating time (Li-ion)F)G)

8 h

System time power supply

CR2032 (3 V lithium battery)

USB standard

2.0

USB Port

USB Type-C®

Wireless connectivity

WLAN

Max. WLAN transmission power

< 20 mW

WLAN operating frequency range

2402–2480 MHz

Weight according to EPTA-Procedure 01:2014

0.61–0.82 kgF)

Dimensions (length × width × height)

115 × 102 × 231 mm

Protection rating (excluding rechargeable batteries, in the vertical position)

IP54

Recommended ambient temperature during charging

0 °C to +35 °C

Permitted ambient temperatures

  • During operation

–10 °C to +50 °C

  • During storage with a rechargeable battery

–20 °C to +50 °C

  • During storage without a rechargeable battery

–20 °C to +70 °C

Recommended rechargeable batteries

GBA 12 V

Recommended chargers

GAL 12…
GAX 18…

A)

In accordance with standard VDI 5585 (average)

B)

In accordance with standard VDI 5585

C)

At an ambient temperature of 20 to 23 °C and an emissivity of > 0.999, measuring distance: 0.3 m, operating time: > 5 min, aperture of 60 mm

D)

Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)

E)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

F)

Depends on battery in use

G)

At an ambient temperature of 20–30 °C

The serial number (4) on the type plate is used to clearly identify your measuring tool.