User interface
The user interface (9) is used to select the working mode and to indicate the status of the power tool.
Status indicators
Power tool status indicator (14) | Meaning/cause | Solution |
|---|---|---|
− | Power tool is switched off | − |
Green | Power tool is switched on and ready to use | – |
Yellow | Critical temperature of electronics reached. | Run the power tool at no load and allow it to cool down until the indicator (14) lights up green again |
Yellow
| Regular power tool maintenance due | Switch off the power tool immediately and send it to the after-sales service. |
Red | Power tool has overheated. | Leave the power tool to cool down. |
Restart protection is triggered. | Switch off the power tool and restore the power supply. Then switch the power tool on again. | |
Lock-on button pressed in "hammer drilling" operating mode | Press the lock-on button again | |
Rotation stop switch activated during operation | Turn the power tool off and on again | |
General error |
If the error persists:
| |
Flashing red
| Rapid shut-off is triggered. | Press the lock-on button and release the on/off switch |
The maintenance indicator (12) goes out as soon as the maintenance has been carried out.
Pressing and holding the reset button (15) for just 5 seconds can reset the notification for regular maintenance.
Selecting the working mode
Press the (16) button for selecting the working mode repeatedly until the working mode you require lights up.
Functions | |
|---|---|
| 100 % working mode: |
| 80 % working mode: |