Connecting the water cooling/dust extraction system

If wet or dry core bits are not sufficiently cooled when drilling, the diamond segments can become damaged or the core bit can jam in the drill hole. You should therefore ensure that the water cooling system provides sufficient cooling when wet drilling, or that the dust extraction system is functioning properly when dry drilling.

When expanding an existing hole, this must be sealed carefully to allow the core bit to be sufficiently cooled.

Connecting the water cooling system

Attach the water connection adapter (14) to the claw coupling (10) and tighten it by turning it clockwise as far as possible.

Close the water cutoff valve (12). Connect a water supply line to the valve adapter (13). The water supply line can be provided from mobile water pressure equipment (accessory) or a stationary water connection.

Connecting the dust extraction system

Do not perform work without taking dust-reducing measures. Using a suitable dust extraction attachment will reduce exposure to harmful dust. Provide good ventilation at the workplace. Always use suitable breathing protection. Use a dust extraction system that is suitable for the material wherever possible. The regulations on the materials being machined that apply in the country of use must be observed.

Requirements for the Dust Extractor

Recommended hose nominal diameter

mm

35

Required vacuum pressureA)

mbar
hPa

≥ 230
≥ 230

Required flow rateA)

l/s
m³/h

≥ 36
≥ 129.6

Recommended filter efficiency

Dust class MB)

A)

Power value at the power tool’s dust extractor connection

B)

According to IEC/EN 60335-2-69

Refer to the dust extractor’s instructions. If there is reduced suction power, stop working and eliminate the cause.

Connecting the dust extractor to the power tool:

  • Attach the extraction adapter (15) to the claw coupling (10) and tighten it by turning it clockwise as far as possible.
  • Attach the extraction hose (17) of the dust extractor to the extraction outlet (16).