User interface (see figure B)

The user interface (6) is used to select the working mode and to switch the power tool on and off.

User interface

Description

The on/off button (20) switches the tool on and off.

The mode button (21) switches between single actuation and contact actuation.

The on/off indicator (19) lights up when the tool is switched on.

The single actuation indicator (22) lights up when single actuation is activated.

The contact actuation indicator (23) lights up when contact actuation is activated.

Status indications

The on/off indicator (19) also signals the status of the power tool as described below:

Status indicator for power tool

Colour

Meaning

Solution

Green

Power tool is switched on and ready to use.

–

Yellow

There is a problem that requires your attention: Critical temperature, battery is almost empty or service is due.

  • Leave the power tool to cool down.
  • Replace or charge the battery.
  • Have maintenance performed.

Red

The power tool is not ready for use.

Reason: Power tool has overheated, battery is empty or mechanical fault.

  • Leave the power tool to cool down.
  • Replace or charge the battery.
  • Have maintenance performed.

Flashing red

  • The second switch was pressed too early.
  • The second switch was not pressed within 5 seconds; the tool switches off automatically.
  • The switches were pressed in the wrong order (e.g. the trigger was pressed before the tool had switched to contact actuation mode)
  • Wait a short time until the status indicator display lights up green.
  • The power tool is ready for use again.
  • Perform the discharging procedure again, observing the correct order of pressing when doing so, or change the actuation mode via the user interface.